Changes in the development version (14 may 2012)

Wednesday, May 16, 2012 - 10:34

|

Features

Interface

  • Selections (facet groups) can be memorized, they are also saved / loaded from GEO files
  • Process control is moved to Global Settings
  • Facet hits panel (lower right) can now be sorted by clicking the column labels
  • Mouse selection is more responsive for large systems: progressbar / hourglass cursor added
  • CAPS LOCK restricts selectable facets to those with a selected vertex
  • Profile Plotter can select the plotted facet
  • Recent... file menu is now in chronological order
  • Facet parameters panel reordered (particle input / output separated)
  • Autoscale button now keeps being turned on (toggle)
  • Blue gradient background
  • On startup, only one viewer is visble

Bugfixes

  • Corrected a calculation error where pressure was divided by the square root of the tempereature
  • Corrected a bug which gave "Invalid outgassing rate" error on some facets
  • Fixed a bug where Molflow crashed after removing facets with a plotted profile
  • Average pressure is now correctly displayed on facets with 0 opacity
  • OpenGL corrections (edge bleeding / Z-fighting problems fixed)